IDDSI Flow Test: What Should You Check When the Flow Stops?

You release the syringe opening, but the drink stops flowing. What does that result tell you?

Before interpreting it, check whether the sample and testing equipment meet the requirements of the IDDSI Flow Test. A blockage can affect the result, so liquid remaining in the syringe does not automatically establish a particular IDDSI level.

For care and kitchen staff, the useful question is what needs checking before the result can be relied on.

Check whether anything is blocking the opening

The IDDSI testing guidance advises checking for lumps when flow suddenly stops.

Small pieces of fruit fibre, seeds or incompletely mixed material may obstruct the syringe opening. If that happens, the remaining volume may reflect the obstruction rather than the drink’s flow characteristics.

Look at the sample and follow your service’s process for investigating an unexpected result. Do not assume that a blocked syringe means the drink is simply thicker than expected.

Follow the manufacturer’s preparation instructions

Preparing the drink and testing it are connected tasks.

Check the instructions for the particular thickener and beverage, including the measurements, mixing method and any required standing time.

A preparation that has not been mixed according to the directions needs attention before its test result is interpreted. Adding more powder or liquid by eye does not establish that the final drink meets the intended level.

If preparation instructions are unclear, seek advice through the appropriate care or product support pathway.

Check the equipment

The syringe used for the IDDSI Flow Test needs to meet the specifications in the official instructions. A 10 mL marking alone does not confirm that a syringe is suitable.

The guidance also specifies using a clean, dry syringe and checking that the opening is clear.

When the result is unexpected, check the equipment alongside the drink preparation. Follow the complete method rather than relying on a familiar syringe or a remembered routine.

Look for air bubbles and foam

Air bubbles and foam can complicate interpretation.

This needs particular attention with carbonated drinks. The official IDDSI guidance notes that foam may appear thick during testing and can release thinner liquid as bubbles collapse.

A foamy appearance or limited flow should therefore not be taken as confirmation that the whole preparation meets the intended level.

Seek appropriate guidance when the sample is difficult to assess, rather than guessing from its appearance.

Level 4 Extremely Thick requires other checks

The IDDSI Flow Test alone does not establish whether a drink meets Level 4 Extremely Thick.

Level 4 Extremely Thick drinks also need assessment using the applicable IDDSI Fork Drip Test and Spoon Tilt Test, alongside the characteristics described in the official definition.

These checks provide information that a syringe result alone cannot establish, including how the sample behaves on a fork and how it leaves a tilted spoon.

Staff should use the current official instructions to perform and interpret the applicable tests. A drink should not be labelled Level 4 simply because it does not flow through the syringe. Official IDDSI testing methods

Test under the intended serving conditions

The drink being tested should reflect the drink being served.

Follow the manufacturer’s preparation directions and the IDDSI guidance about testing under intended serving conditions, particularly temperature.

If the test was interrupted or the method was not followed correctly, repeat it appropriately. Do not estimate what the result might have been.

IDDSI testing examines the characteristics of a prepared food or drink.

It does not determine which thickness a person needs. That requires individual assessment and discussion with the person and their treating professionals.

Even when a drink meets a particular IDDSI level, staff still need to check that it matches the person’s current swallowing recommendations.

Ask for help when the result is unclear

If the preparation or result remains uncertain, follow your service’s process for obtaining advice and arranging an appropriate drink.

Do not offer an uncertain preparation to see how the person manages it.

When communicating the concern, describe what you observed. For example, saying that flow started and then stopped, with visible particles in the sample, gives the next person something specific to investigate.

Help staff understand the testing methods

Practical IDDSI training can give care and kitchen teams opportunities to ask questions about equipment, preparation and the tests that apply to different levels.

Understanding when a result needs further checking is part of learning to use the methods appropriately.

Swallowing & Dysphagia Support provides IDDSI training for care and kitchen teams. Contact us to discuss training for your Sydney organisation and the practical questions your staff would like to address.

This article provides general education. Follow the current official IDDSI definitions and testing methods, the manufacturer’s instructions and the person’s individual swallowing recommendations.

Previous
Previous

3D Food Printing and Dysphagia: Exploring New Possibilities for Texture-Modified Meals

Next
Next

How Many Scoops or Pumps Do You Need? Why Thickener Instructions Matter