Common IDDSI Testing Mistakes - How Teams Can Improve Consistency

IDDSI testing helps teams describe and check the texture of foods and the flow of drinks. However, the result is only useful when the correct test, equipment, sample and technique are used.

Common mistakes include using the wrong syringe, testing food at a different temperature from when it will be served, changing the published method, testing an unrepresentative sample or assuming that a recipe will always produce the same result.

Common mistakes include using the wrong syringe, testing food at a different temperature from when it will be served, altering the testing method, testing an unrepresentative sample, or assuming that a recipe will always produce the same result.

Consistent IDDSI testing requires clear procedures, suitable equipment and practical staff training—not guesswork.

Why does consistent IDDSI testing matter?

The International Dysphagia Diet Standardisation Initiative, known as IDDSI, provides a standardised framework for describing texture-modified foods and thickened drinks.

A person may have an individual recommendation for food and drinks described using IDDSI levels. Carers, support workers, nurses, cooks and food-service staff need to understand how to prepare, identify and test these items according to their responsibilities.

IDDSI testing describes the properties of a food or drink. It does not determine which level is appropriate for an individual. That decision requires an individual swallowing assessment and recommendation from an appropriately qualified health professional.

Mistake 1: Using the wrong test

Different IDDSI levels and food or drink types require different testing methods. One test cannot answer every question about an item.

Depending on the food or drink, the relevant methods may include:

  • the IDDSI Flow Test

  • the Fork Drip Test

  • the Spoon Tilt Test

  • the Fork Pressure Test

  • the Chopstick Test

  • the Finger Test

  • checks of particle size or food characteristics

Some items may require more than one test to confirm that they meet all the relevant requirements.

Teams should use the current official IDDSI testing instructions rather than relying on memory, an old handout or an informal demonstration.

Mistake 2: Assuming any 10 mL syringe will work

A common error is assuming that any syringe labelled “10 mL” can be used for the IDDSI Flow Test.

The dimensions of the syringe affect the result. Two syringes with the same stated capacity may have different barrel lengths or nozzle dimensions and may not produce the same flow result.

Check the current official IDDSI instructions for the required syringe specifications. Organisations should also make sure that appropriate syringes are available wherever testing is expected to occur.

If the approved syringe is replaced with a different product, confirm that the new syringe meets the IDDSI requirements before using it for testing.

Mistake 3: Changing the timing or technique

The IDDSI Flow Test follows a defined method. Changes to the timing, how the nozzle is released or blocked, the syringe position or how the result is read may affect the outcome.

Common technique errors include:

  • starting or stopping the timer at the wrong point

  • holding the syringe at an angle

  • covering or releasing the nozzle inconsistently

  • reading the result from the wrong position

  • repeating the test with different timing

  • estimating the result instead of following the full method

Written instructions are helpful, but practical demonstration and observation are often needed. Watching another person complete a test does not automatically mean a staff member can perform it reliably.

Mistake 4: Testing the wrong sample

The sample being tested should represent the food or drink that will be served.

Results may be misleading if staff:

  • test a freshly prepared sample but serve it much later

  • test liquid from the top while thicker material has settled

  • test one part of a mixed meal but not the component being served

  • test a smooth section while ignoring lumps, crusts or separate liquid

  • test one portion of a batch that has not been mixed consistently

  • test a different product from the one given to the person

Where appropriate, the sample should be mixed and selected according to the relevant procedure so that it represents the item being served.

Mistake 5: Ignoring temperature and standing time

The flow and texture of food and drinks can change over time.

A thickened drink may continue to change after preparation. A hot meal may become firmer as it cools. Ice cream may melt. A sauce may separate or thicken. Food may also change during refrigeration, reheating or transport.

Testing only at the point of preparation may not show what the person will receive at the table.

Teams should consider:

  • when the item is prepared

  • how long it stands before service

  • the temperature at which it is served

  • whether it is reheated, chilled or transported

  • whether it separates or forms a skin

  • whether its texture changes during the meal

The testing point should be clearly defined within the organisation’s preparation and service process.

Mistake 6: Applying inconsistent pressure during food testing

Some IDDSI food tests involve applying pressure with a fork, spoon, chopsticks or fingers. Results can vary when staff use very different amounts of pressure or apply the test inconsistently.

Technique should follow the current official IDDSI instructions. Staff may need supervised practice and feedback to understand how to apply the method reliably.

If two staff members repeatedly obtain different results from the same sample, do not simply select the preferred result. Review:

  • whether they used the same test

  • whether the sample was consistent

  • whether the same equipment was used

  • whether temperature or standing time changed

  • how each person applied the testing method

  • whether both staff members followed the current instructions

Unresolved differences should be escalated through the organisation’s quality or clinical process.

Mistake 7: Checking only softness

A food being soft does not automatically mean that it meets all the requirements of a particular IDDSI level.

Depending on the level, other characteristics may also matter, such as:

  • particle size

  • whether liquid separates from the food

  • whether the food is sticky

  • whether it holds together

  • whether it can be broken down using the relevant pressure

  • whether it contains hard, fibrous, stringy or mixed-texture components

Teams should assess all relevant characteristics rather than relying on appearance or softness alone.

Mistake 8: Assuming a blender guarantees the result

Using a blender does not automatically produce a particular IDDSI level.

The final texture can be affected by:

  • the ingredients

  • the amount and type of liquid added

  • blending time

  • batch size

  • equipment performance

  • temperature

  • standing time

  • reheating

  • natural variation between ingredients

A food should be tested in its final prepared form according to the organisation’s procedure. The appliance used does not replace testing.

Mistake 9: Treating recipes as infallible

A standardised recipe can improve consistency, but it cannot account for every variation.

Results may change when staff:

  • substitute ingredients or brands

  • estimate quantities

  • alter the amount of liquid

  • change the cooking time

  • prepare a different batch size

  • use different equipment

  • reheat the meal differently

  • do not follow the documented sequence

If substitutions are necessary, the final item may need to be checked again. Organisations should clearly define who can approve substitutions and what testing is required.

Mistake 10: Recording the label without completing the test

Writing an IDDSI level on a container does not prove that the item meets that level.

Labels are important for communication, but they must reflect an item that has been prepared and checked according to the relevant procedure.

Documentation may need to record:

  • the item or batch tested

  • the date and time

  • the temperature or stage of service, where relevant

  • the testing method used

  • the result

  • who completed the test

  • what action was taken if the item did not meet requirements

The exact documentation required will depend on the organisation’s quality system and the staff member’s role.

Mistake 11: Guessing when a result is borderline

A borderline or unexpected result should not be adjusted informally until it “looks right”.

Staff should follow the organisation’s procedure. This may involve:

  1. checking the official testing instructions

  2. repeating the test correctly with a representative sample

  3. checking the equipment, timing and technique

  4. reviewing the recipe and preparation process

  5. asking an appropriately trained person to observe or repeat the test

  6. escalating the result if it remains unclear

Do not serve an item under a preferred IDDSI label simply because the team expected it to reach that level.

Mistake 12: Assuming that passing a test makes an item suitable for everyone

An IDDSI test describes characteristics of a particular food or drink. It does not determine whether that item is appropriate for a particular person.

Individual suitability depends on the person’s current swallowing recommendations and other documented requirements.

A person may also have needs relating to:

  • assistance or supervision

  • positioning and pacing

  • allergies or intolerances

  • nutrition and hydration

  • medication

  • equipment

  • communication

  • personal and cultural preferences

Passing an IDDSI test does not replace the person’s mealtime management plan.

How teams can improve consistency

Reliable testing depends on the whole system, not only the individual staff member.

Organisations can improve consistency by:

  • using current official IDDSI instructions

  • providing the correct equipment at the point of testing

  • defining which tests apply to each product or process

  • establishing standardised recipes and preparation methods

  • specifying when and at what temperature testing occurs

  • documenting approved products and substitutions

  • using clear visual work instructions

  • providing hands-on training and observed practice

  • checking staff technique rather than relying only on course completion

  • documenting results according to the organisation’s procedure

  • reviewing repeated failures for underlying process problems

  • providing a clear escalation pathway for uncertain results

When an item repeatedly fails testing, investigate the process. The cause may involve ingredients, measurements, temperature, standing time, equipment, transport, staff technique or an unsuitable recipe.

Frequently asked questions

Can any 10 mL syringe be used for the IDDSI Flow Test?

No. Syringes with the same stated capacity can have different dimensions, which may affect the result. Check the current official IDDSI specifications and make sure the approved equipment is consistently available.

Should every meal or drink be tested?

Yes. Testing frequency depends on the item, preparation method, product consistency and the organisation’s quality procedures. The organisation should clearly define what is tested, when testing occurs and who is responsible.

What if two staff members obtain different results?

Repeat the test using the same representative sample, method and equipment. Observe each person’s technique and check factors such as temperature and timing. Escalate unresolved differences rather than selecting the preferred result.

Can a blender guarantee an IDDSI level?

No. A blender is only part of the preparation process. Ingredients, quantities, blending time, temperature and standing time can affect the final texture. The finished food should be checked using the relevant IDDSI methods.

Does passing one test confirm the IDDSI level?

No. Some foods and drinks require more than one check because different tests examine different characteristics. Follow the current official instructions for the food and intended level.

Does passing an IDDSI test mean the item is suitable for a particular person?

No. Testing describes the food or drink. The person’s current clinical recommendations determine which food textures and drink thicknesses are appropriate for them.

What to do next

If staff obtain inconsistent results or are unsure how to apply IDDSI testing methods, review the process before treating the issue as an individual mistake.

Swallowing & Dysphagia Support provides practical IDDSI training for carers, support workers, nurses, cooks, food-service teams and organisations.

Contact Swallowing & Dysphagia Support to discuss practical training for your team.

Important information

This article provides general education. It cannot determine an individual’s food texture, drink thickness, suitability for oral intake, treatment, supervision or level of swallowing risk.

Always use current official IDDSI resources and follow the person’s individual swallowing or mealtime management plan.

This article and Swallowing & Dysphagia Support training are independently developed educational materials. They are not official IDDSI resources, education programs or certification, and they do not replace current materials available from IDDSI.

About the author

Written for Swallowing & Dysphagia Support and clinically reviewed by Vanessa Chan, Speech Pathologist.

Sources and further reading

Next
Next

When Does a Change in Health Require a New Swallowing Assessment?